Inhaltsverzeichnis
The SKDS Protocol
to be moved onto the OpenOnBoardDiagnostics- Homepage
Actually „protocol“ only means the communication between two SKDS instances through Skype, but as this communication might also been done e.g. via TCP/IP, it was decided to publish the protocol here for possible third party implementations.
The communication is based on the exchange of XML-Strings, meaning that all information is packed into an XML format. The rootnode is always <SKDS>
Initiate a Connection
The remote link is initiated by the remote SKDS (the so called Master) by sending a request to the local SKDS (to which the modules are physically connected, the so called Slave):
<SKDS><MASTER></MASTER></SKDS>
If the slave accepts the request, it sends back the positive response
<SKDS><SLAVE></SLAVE></SKDS>
or in the case of any rejection it sends a negative response
<SKDS><BUSY>reason of rejection</BUSY></SKDS>
where the „reason of rejection“ is displayed at the Master as feedback to the user, as to why the connection was rejected.
Close a Connection
To close a connection, each side can send a <BUSY>- Tag to close:
<SKDS><BUSY>reason of rejection</BUSY></SKDS>
Telegram Exchange
Sending a Request
To request data from the module, the Master sends a message containing the request. As the handling of old KWP-telegrams or today's UDS-telegrams are different, there are 2 different types used:
<SKDS><FDS_REQ>packed KWP data</FDS_REQ></SKDS>
or
<SKDS><GGDS_REQ>packed UDS data<GGDS_REQ></SKDS>
packed KWP data
The packet KWP data consists of a sequence of the following tag and value combinations:
Tag | Content |
---|---|
SA | Sourceaddress of the Tester as numeric value, but only the last byte (0x7FE → 0x7E → 254) |
TA | Targetaddress of the module as numeric value, but only the last byte (0x77E → 0x7E → 246) |
LEN | Length of the telegram in bytes as numeric value |
ERR | error byte as numeric value |
DATA | base64 coded telegram content |
packed UDS data
The packet UDS data consists of the same sequence as KWP, plus one additional Tag:
Tag | Content |
---|---|
SA | Sourceaddress of the Tester as numeric value, but only the last byte (0x7FE → 0x7E → 254) |
TA | Targetaddress of the module as numeric value, but only the last byte (0x77E → 0x7E → 246) |
LEN | Length of the telegram in bytes as numeric value |
ERR | error byte as numeric value |
DATA | base64 coded telegram content |
OLDFRAME | 0 or 1, reserved for later extensions |
Sending the Response
After the slave has forwarded the request to the module and received the answer, it sends the result back to the master by
<SKDS><FDS_ANS>packed KWP data</FDS_ANS></SKDS>
or
<SKDS><GGDS_ANS>packed UDS data<GGDS_ANS></SKDS>
where again the packed data contains the details as shown above
Module Changes
When the slave detects an operational state feedback from a module in the communication flow, it reports this operational state back to the master:
<SKDS><SCANNER_EVENT_MOD_STATE><ID>id</ID><TEXT>text</SCANNER_EVENT_MOD_STATE></SKDS>
with the data
Tag | Content |
---|---|
ID | Address of the Module as numeric value, but only the last byte (0x7FE → 0x7E → 254) |
TEXT | Operational State of the module in hexadecimal writing (e.g. $81) |
When in contrast the Master „deletes“ a module ID by executing the ChangeID-command or by closing a window, the master sends the following command to the slave, mainly to switch off the tester present message of that module on the slave side:
<SKDS><SCANNER_COMMAND_MOD_REMOVE><ID>id</ID></SCANNER_COMMAND_MOD_REMOVE></SKDS>
again with the data
Tag | Content |
---|---|
ID | Address of the Module as numeric value, but only the last byte (0x7FE → 0x7E → 254) |
Base64 Coding
to be corrected
As shown above, the telegram data itself is transfered as base64 coded binary data. For own implementations it is important to know that SKDS uses a slighty different character set compared to the base64 standard 1).
The character set used by SKDS is